Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Behav Res Methods ; 2023 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-37507649

RESUMO

A guideline is proposed that comprises the minimum items to be reported in research studies involving an eye tracker and human or non-human primate participant(s). This guideline was developed over a 3-year period using a consensus-based process via an open invitation to the international eye tracking community. This guideline will be reviewed at maximum intervals of 4 years.

2.
Invest Ophthalmol Vis Sci ; 63(2): 28, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35195683

RESUMO

Purpose: Children with Down's syndrome (DS) are known to have poorer visual acuity than neurotypical children. One report has shown that children with DS and nystagmus also have poor acuity when compared to typical children with nystagmus. What has not been established is the extent of any acuity deficit due to nystagmus and whether nystagmus affects refractive error within a population with DS. Methods: Clinical records from the Cardiff University Down's Syndrome Vision Research Unit were examined retrospectively. Binocular visual acuity and refraction data were available for 50 children who had DS and nystagmus and 176 children who had DS but no nystagmus. Data were compared between the two groups and with published data for neurotypical children with nystagmus. Results: The study confirms the deficit in acuity in DS, compared to neurotypical children, of approximately 0.2 logMAR and shows a deficit attributable to nystagmus of a further 0.2 logMAR beyond the first year of life. Children with both DS and nystagmus clearly have a significant additional impairment. Children with DS have a wide range of refractive errors, but nystagmus increases the likelihood of myopia. Prevalence and axis direction of astigmatism, on the other hand, appear unaffected by nystagmus. Conclusions: Nystagmus confers an additional visual impairment on children with DS and must be recognized as such by families and educators. Children with both DS and nystagmus clearly need targeted support.


Assuntos
Síndrome de Down/fisiopatologia , Nistagmo Patológico/fisiopatologia , Erros de Refração/fisiopatologia , Transtornos da Visão/fisiopatologia , Acuidade Visual/fisiologia , Astigmatismo/fisiopatologia , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Nistagmo Patológico/diagnóstico , Refração Ocular/fisiologia , Estudos Retrospectivos , Testes Visuais , Visão Binocular/fisiologia
3.
Invest Ophthalmol Vis Sci ; 61(6): 15, 2020 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-32526031

RESUMO

Purpose: Infantile nystagmus (IN) presents with continuous, predominantly horizontal eye oscillations. It remains controversial whether those with IN have normal horizontal pursuit, while vertical pursuit has rarely been studied. We examined whether there are pursuit deficits associated with IN by investigating the effect of target direction, velocity, and amplitude. Methods: Twelve adults with idiopathic IN performed a pursuit task, a 0.4° dot moved either horizontally or vertically at 8 or 16°/s, through amplitudes of 8°, 16°, or 32°. Accuracy and precision errors were computed as bivariate probability density functions of target-relative eye velocities. Results: Eye velocity was less precise along the horizontal axis during both horizontal and vertical pursuit, reflecting the primary axis of the eye oscillation. Mean accuracy error along the target trajectory during vertical pursuit was just as impaired as during horizontal pursuit. There was a greater error in accuracy along the target trajectory for 16°/s targets than 8°/s. Finally, targets that oscillated at 2.0 Hz had a greater error in accuracy along the target trajectory than frequencies of 1.0 Hz or 0.5 Hz. When studied using the same experimental protocol, pursuit performance for typical observers was always better. Conclusions: These findings strongly support our hypothesis of severe deficits in pursuit accuracy in observers with IN for horizontally and vertically moving targets, as well as for targets that move at higher speeds or oscillate more quickly. Overall, IN pursuit impairment appears to have previously been underestimated, highlighting a need for further quantitative studies of dynamic visual function in those with IN.


Assuntos
Doenças Genéticas Ligadas ao Cromossomo X/fisiopatologia , Nistagmo Congênito/fisiopatologia , Acompanhamento Ocular Uniforme/fisiologia , Adolescente , Adulto , Idoso , Movimentos Oculares/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Percepção de Movimento , Oftalmoscopia , Reprodutibilidade dos Testes , Microscopia com Lâmpada de Fenda , Tomografia de Coerência Óptica , Adulto Jovem
4.
Transl Vis Sci Technol ; 8(5): 7, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31588372

RESUMO

PURPOSE: Small moving targets are followed by pursuit eye movements, with success ubiquitously defined by gain. Gain quantifies accuracy, rather than precision, and only for eye movements along the target trajectory. Analogous to previous studies of fixation, we analyzed pursuit performance in two dimensions as a function of target direction, velocity, and amplitude. As a subsidiary experiment, we compared pursuit performance against that of fixation. METHODS: Eye position was recorded from 15 observers during pursuit. The target was a 0.4° dot that moved across a large screen at 8°/s or 16°/s, either horizontally or vertically, through peak-to-peak amplitudes of 8°, 16°, or 32°. Two-dimensional eye velocity was expressed relative to the target, and a bivariate probability density function computed to obtain accuracy and precision. As a comparison, identical metrics were derived from fixation data. RESULTS: For all target directions, eye velocity was less precise along the target trajectory. Eye velocities orthogonal to the target trajectory were more accurate during vertical pursuit than horizontal. Pursuit accuracy and precision along and orthogonal to the target trajectory decreased at the higher target velocity. Accuracy along the target trajectory decreased with smaller target amplitudes. CONCLUSIONS: Orthogonal to the target trajectory, pursuit was inaccurate and imprecise. Compared to fixation, pursuit was less precise and less accurate even when following the stimulus that gave the best performance. TRANSLATIONAL RELEVANCE: This analytical approach may help the detection of subtle deficits in slow phase eye movements that could be used as biomarkers for disease progression and/or treatment.

6.
Behav Res Methods ; 51(5): 2074-2084, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30875024

RESUMO

Infantile nystagmus (IN) describes a regular, repetitive movement of the eyes. A characteristic feature of each cycle of the IN eye movement waveform is a period in which the eyes are moving at minimal velocity. This so-called "foveation" period has long been considered the basis for the best vision in individuals with IN. In recent years, the technology for measuring eye movements has improved considerably, but there remains the challenge of calibrating the direction of gaze in tracking systems when the eyes are continuously moving. Identifying portions of the nystagmus waveform suitable for calibration typically involves time-consuming manual selection of the foveation periods from the eye trace. Without an accurate calibration, the exact parameters of the waveform cannot be determined. In this study, we present an automated method for segmenting IN waveforms with the purpose of determining the foveation positions to be used for calibration of an eye tracker. On average, the "point of regard" was found to be within 0.21° of that determined by hand-marking by an expert observer. This method enables rapid clinical quantification of waveforms and the possibility of gaze-contingent research paradigms being performed with this patient group.


Assuntos
Calibragem , Medições dos Movimentos Oculares , Automação , Movimentos Oculares , Humanos , Nistagmo Patológico , Acuidade Visual
7.
Optom Vis Sci ; 89(9): 1385-94, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22885785

RESUMO

PURPOSE: In performing search tasks, the visual system encodes information across the visual field at a resolution inversely related to eccentricity and deploys saccades to place visually interesting targets upon the fovea, where resolution is highest. The serial process of fixation, punctuated by saccadic eye movements, continues until the desired target has been located. Loss of central vision restricts the ability to resolve the high spatial information of a target, interfering with this visual search process. We investigate oculomotor adaptations to central visual field loss with gaze-contingent artificial scotomas. METHODS: Spatial distortions were placed at random locations in 25° square natural scenes. Gaze-contingent artificial central scotomas were updated at the screen rate (75 Hz) based on a 250 Hz eye tracker. Eight subjects searched the natural scene for the spatial distortion and indicated its location using a mouse-controlled cursor. RESULTS: As the central scotoma size increased, the mean search time increased [F(3,28) = 5.27, p = 0.05], and the spatial distribution of gaze points during fixation increased significantly along the x [F(3,28) = 6.33, p = 0.002] and y [F(3,28) = 3.32, p = 0.034] axes. Oculomotor patterns of fixation duration, saccade size, and saccade duration did not change significantly, regardless of scotoma size. CONCLUSIONS: There is limited automatic adaptation of the oculomotor system after simulated central vision loss.


Assuntos
Adaptação Ocular/fisiologia , Memória/fisiologia , Reconhecimento Visual de Modelos/fisiologia , Estimulação Luminosa/métodos , Movimentos Sacádicos/fisiologia , Escotoma/fisiopatologia , Privação Sensorial , Adulto , Seguimentos , Humanos , Campos Visuais , Adulto Jovem
8.
Ophthalmic Physiol Opt ; 28(5): 448-56, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18761482

RESUMO

PURPOSE: To investigate the effects of real and simulated age-related changes in crystalline lens yellowing on Farnsworth-Munsell (FM) 100 hue performance. METHODS: FM 100 hue total and partial error scores (PES) were measured in a group of younger (n=10, mean age=22.2+/-2.65 years) and a group of older (n=10, mean age=54.5+/-2.64 years) normal observers along with psychophysical estimates of crystalline lens optical density and pupil size. Three younger observers underwent repeated FM 100 hue testing under a variety of simulated age-related lens yellowing conditions, using filters with well-defined transmittance properties which attempted to mimic the real age-related lens yellowing changes of the older group. RESULTS: FM 100 hue total and PES were significantly higher in the older age group compared with the younger group (p<0.01). Lens density measures were significantly higher in the older age group compared with the young group (p<0.01), but showed less scatter than individual FM 100 hue error scores. Simulated lens yellowing in the three younger observers, equivalent to the level of that of the older observers, did not affect any of their FM 100 hue total or PES. CONCLUSIONS: Simulation of age-related lens yellowing in younger observers has little effect on FM 100 hue error score. A variety of other factors such as pupil size, background illumination level, iris colour and macular pigment density may contribute to the age-related increase in FM 100 hue scores.


Assuntos
Testes de Percepção de Cores/instrumentação , Defeitos da Visão Cromática/fisiopatologia , Cristalino/fisiologia , Adulto , Fatores Etários , Testes de Percepção de Cores/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Simulação de Paciente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...